Caution
Grafana Agent has reached End-of-Life (EOL) on November 1, 2025. Agent is no longer receiving vendor support and will no longer receive security or bug fixes. Current users of Agent Static mode, Agent Flow mode, and Agent Operator should proceed with migrating to Grafana Alloy. If you have already migrated to Alloy, no further action is required. Read more about why we recommend migrating to Grafana Alloy.
loki.source.syslog
loki.source.syslog listens for syslog messages over TCP or UDP connections
and forwards them to other loki.* components. The messages must be compliant
with the RFC5424 format.
The component starts a new syslog listener for each of the given config
blocks and fans out incoming entries to the list of receivers in forward_to.
Multiple loki.source.syslog components can be specified by giving them
different labels.
Usage
loki.source.syslog "LABEL" {
listener {
address = "LISTEN_ADDRESS"
}
...
forward_to = RECEIVER_LIST
}Arguments
loki.source.syslog supports the following arguments:
The relabel_rules field can make use of the rules export value from a
loki.relabel component to apply one or more relabeling rules to log entries
before they’re forwarded to the list of receivers in forward_to.
Blocks
The following blocks are supported inside the definition of
loki.source.syslog:
The > symbol indicates deeper levels of nesting. For example, config > tls_config
refers to a tls_config block defined inside a config block.
listener block
The listener block defines the listen address and protocol where the listener
expects syslog messages to be sent to, as well as its behavior when receiving
messages.
The following arguments can be used to configure a listener. Only the
address field is required and any omitted fields take their default
values.
By default, the component assigns the log entry timestamp as the time it was processed.
The labels map is applied to every message that the component reads.
All header fields from the parsed RFC5424 messages are brought in as
internal labels, prefixed with __syslog_.
If label_structured_data is set, structured data in the syslog header is also
translated to internal labels in the form of
__syslog_message_sd_<ID>_<KEY>. For example, a structured data entry of
[example@99999 test="yes"] becomes the label
__syslog_message_sd_example_99999_test with the value "yes".
tls_config block
The following pairs of arguments are mutually exclusive and can’t both be set simultaneously:
ca_pemandca_filecert_pemandcert_filekey_pemandkey_file
When configuring client authentication, both the client certificate (using
cert_pem or cert_file) and the client key (using key_pem or key_file)
must be provided.
When min_version is not provided, the minimum acceptable TLS version is
inherited from Go’s default minimum version, TLS 1.2. If min_version is
provided, it must be set to one of the following strings:
"TLS10"(TLS 1.0)"TLS11"(TLS 1.1)"TLS12"(TLS 1.2)"TLS13"(TLS 1.3)
Exported fields
loki.source.syslog does not export any fields.
Component health
loki.source.syslog is only reported as unhealthy if given an invalid
configuration.
Debug information
loki.source.syslog exposes some debug information per syslog listener:
- Whether the listener is currently running.
- The listen address.
- The labels that the listener applies to incoming log entries.
Debug metrics
loki_source_syslog_entries_total(counter): Total number of successful entries sent to the syslog component.loki_source_syslog_parsing_errors_total(counter): Total number of parsing errors while receiving syslog messages.loki_source_syslog_empty_messages_total(counter): Total number of empty messages received from the syslog component.
Example
This example listens for Syslog messages in valid RFC5424 format over TCP and
UDP in the specified ports and forwards them to a loki.write component.
loki.source.syslog "local" {
listener {
address = "127.0.0.1:51893"
labels = { component = "loki.source.syslog", protocol = "tcp" }
}
listener {
address = "127.0.0.1:51898"
protocol = "udp"
labels = { component = "loki.source.syslog", protocol = "udp"}
}
forward_to = [loki.write.local.receiver]
}
loki.write "local" {
endpoint {
url = "loki:3100/api/v1/push"
}
}Compatible components
loki.source.syslog can accept arguments from the following components:
- Components that export Loki
LogsReceiver
Note
Connecting some components may not be sensible or components may require further configuration to make the connection work correctly. Refer to the linked documentation for more details.



